NMHU Commencement 2020 details are here!

Ilfeld Auditorium Facility

Calendar of Events | Cineflix | Contact | Directions | Facility | Rental Agreement | Support | Tickets

Ilfeld Auditorium Technical Information

DSC00908

Click here to download a complete version of Ilfeld Auditorium’s Technical Specifications.  (PDF)

Grid_steel_3

Ilfeld Auditorium Manager: Donna Martinez
505.454.3238
martinezda@nmhu.edu
Office located on Highlands campus, Media Arts West, studio 103.
ilfeld@nmhu.edu
Backstage: 505.454.3183

Seating Capacity:
Lower Level:     295
Balcony:            411
Total capacity:  706

Stage Information:
Type: Proscenium
Floor: Matte black finish.
Stage traps:  9‘ wide (SR-SL) x 3‘ 7‘‘ deep (US-DS)
14‘‘ SL of C
DS edge of trap 23‘9‘‘ from plaster line
Width:
Wing to wing: 56′ 3″
Proscenium Opening: 33‘ 10‘‘
CS to SR Wall: 39‘ 9‘
CS to SL Wall: 26‘ 6‘‘
Depth:
Plaster Line to US Wall: 30‘ 9‘‘
Apron Lip to Plaster Line: 10‘ 6‘‘
Apron Lip to US Wall: 41‘ 3‘‘
Height:
Stage Floor from House Floor (at C Apron edge): 3‘8‘‘
Proscenium Height: 23‘ 3‘‘
Maximum Batten Height: 37‘ 3‘‘
Apron:
Shape: rectangular
Width: 35‘ 9‘‘
Depth: 10‘6‘‘
Pit:
Access: Through green/dressing rooms (located downstairs SL)
Note: Orchestra pit is semi-permanently covered by the apron.

Rigging:
Consists of single-purchase counterweight system. Rail located at stage level SR.
Please note:  House Curtain is a traveler (pulley located stage level SR).
Midstage Traveler pulley located stage level SR.

Maximum Arbor capacity:     1300 lbs.

Batten Length:         42’

Maxium Batten Height:     37‘ 3‘‘
Trim of Electrics 1-4:        21‘ 10‘‘
Trim of Electric 5:        approx.      20‘/variable

Grid Dimensions:
There are 4 I Beams located  44’113/8” above the stage floor
5’111/4” SR of Center, 17’115/8” SR of Center, 6’3/4” SL of Center
and 18’3/8” SL of Center. I Beams are 8” wide X 117/8” high

Hanging Plot:
Line Set:    Description:    Distance from PL
1                    Teaser                        3′ 10”
2                   Main Curtain            4′ 10”
3                   Border 0                     5′ 8”
4                   Electric 1                    6′ 10”
5                   Movie Screen            8′ 2”
6                   Border 1                      9′
7                   Legs 1                          9′ 7”
8                                                        10′ 5”
9                   Electric 2                  11′ 2”
10                                                   12′
11                                                   12′ 11”
12                 Border 2                   13′ 8”
13                 Legs 2                        14′ 5”
14                (scrim)                       15′
15                Electric 3                   15′ 4”
16                                                     17′ 7”
17                Border 3                    18′ 7”
18             Midstage Traveler    19′ 5”
(Legs 3)
19                                                   20′ 4”
20              Electric 4                  21′ 2”
21                                                   22′ 1”
22              Border 4                   22′ 11”
23                                                  23′ 7”
24              Legs 4                       24′ 6”
25              Electric 5                 25′ 10”
26                                                 27′ 2”
27              Border 5                  27′ 11”
28             Cyclorama            29′ 2”
29                                                30′ 4”
30              Sky drop                 31′ 4”

Loading Area:
Located at street level.
Loading door is 6’6” wide X 8’3” tall, and opens directly into the SL wing onto an 8’ X 4’ platform, 3’ above stage floor.
Ramp 2’3” wide and 9’9” long is available

Best Position to “Call Show”:
Stage Left or Stage Right Wing. ClearCom hookups SL and SR.

Power:
200 amps of 208 Volt 3 phase located in the down stage left wing.
All cam connectors are female.

Sound Control:
Control Booth is located rear house left with removable windows. A temporary mix position can be situated in the rear of house, center, 5’11” deep x 25’ wide, under the balcony and 42’ from the lip of the stage.

Full sound specifications available upon request.

Lighting:
Control Booth is located rear house right with removable windows. Lighting control can be located virtually anywhere in the theatre.

Dimming and Control:
ETC Sensor 192 dimmers, (16 dimmers dedicated to house lights)
ETC Express 125
ETC Express 24/48
Remote Focus Unit
75’ DMX cable

Projection Location: Typically, center balcony rail. Approximate distance from this distance to:
DS Screen    – 52’
Cyc               – 75’

Spot Booth:
Located rear balcony center with two Altman Comets. Has ClearCom hookup.

Dressing Rooms:
Only accessible by stairway in SL wing. There are two bathrooms, two large dressing rooms with locking doors, counters, mirrors, and mirror lights, and one “common”/green room area with counters, mirrors, and mirror lights. Maximum capacity of dressing rooms: 90. Maximum capacity of backstage area: 140.
Ironing board and iron available for use, but the theatre has no washer or dryer and no phone line.